Inliners International
Posted By: vincerael engien wont start - 11/13/08 03:14 AM
its a 230 it starts everyday fist turn today it just turns so i check to see if any spark dont seem like it can it be the points or condenser the coil is new thanks
Posted By: Nexxussian Re: engien wont start - 11/13/08 05:49 AM
No spark (if I read that right)? How's the ballast resisitor, is the ground lead from thre breaker plate to the dizzy housing still good? Are you getting power to the ballast? (asuming here your coil isn't the internal ballast type, if it is, disregard that)?
Posted By: gearhead Re: engien wont start - 11/13/08 07:46 PM
Take the cap off and turn it over to see if the points are sparking or not.
If not, use a test light to determine if you have power going from the coil to the distributor.
If there's power at the coil, but no spark at the points, it's probably the condenser or very worn points.
Posted By: vincerael Re: engien wont start - 11/13/08 08:19 PM
it was the points thanks everyone