#45104 11/13/08 03:14 AM
Joined: Jul 2008
Posts: 14
V
Active BB Member
OP Offline
Active BB Member
V
Joined: Jul 2008
Posts: 14
its a 230 it starts everyday fist turn today it just turns so i check to see if any spark dont seem like it can it be the points or condenser the coil is new thanks

Joined: Jun 2007
Posts: 1,411
N
1000 Post Club
*****
Offline
1000 Post Club
*****
N
Joined: Jun 2007
Posts: 1,411
No spark (if I read that right)? How's the ballast resisitor, is the ground lead from thre breaker plate to the dizzy housing still good? Are you getting power to the ballast? (asuming here your coil isn't the internal ballast type, if it is, disregard that)?


My, what a steep learning curve. Erik II#5155
Joined: Jul 2000
Posts: 1,613
G
1000 Post Club
Offline
1000 Post Club
G
Joined: Jul 2000
Posts: 1,613
Take the cap off and turn it over to see if the points are sparking or not.
If not, use a test light to determine if you have power going from the coil to the distributor.
If there's power at the coil, but no spark at the points, it's probably the condenser or very worn points.


I.I. #3174
Joined: Jul 2008
Posts: 14
V
Active BB Member
OP Offline
Active BB Member
V
Joined: Jul 2008
Posts: 14
it was the points thanks everyone


Moderated by  stock49, Twisted6, will6er 

Link Copied to Clipboard
Who's Online Now
0 members (), 358 guests, and 49 robots.
Key: Admin, Global Mod, Mod
Newest Members
SSG Pohlman, castironphil, uncle dave, trustedmedications20, Jsmay101
6,786 Registered Users
Sponsored Advertisement
Sponsored Advertisement
This Space is Available
Powered by UBB.threads™ PHP Forum Software 7.7.5